BQPKG - FC-70 FLUORINET BRAND ELECTRONIC LIQUID

Product Identification

Product ID:FC-70 FLUORINET BRAND ELECTRONIC LIQUID
MSDS Date:04/11/1989
FSC:6810
NIIN:00N012602
MSDS Number: BQPKG

Responsible Party
MINNESOTA MINING & MFG CO INDUSTRIAL CHEM PRODUCTS
3M CTR
ST PAUL, MN 55144
US

Emergency Phone: 612-733-5454

Info Phone: 612-733-1000

Cage: 28112

Contractor
MINNESOTA MINING AND MFG CO PERFOMANCE CHEM AND FLUIDS DIV
SAINT PAUL, MN 55144-1000 US

Telephone: 800-364-3577/651-737-6501

Cage: 28112

Ingredients

PERFLUORO COMPOUNDS (C15-18)

CAS: 86508-42-1

Fraction By Weight: 100%

OSHA PEL N/K

ACGIH TLV: N/K


AIR CURRENTS ARE PRESENT,MIN CAPTURE VELOCITY SHOULD

RTECS: 9999999ZZ

OSHA PEL N/K

ACGIH TLV: N/K


CONTAMINANTS MAY BE INTRODUCED THAT MAY BE

RTECS: 9999999ZZ

OSHA PEL N/K

ACGIH TLV: N/K

Hazards

LD50 LC50 Mixture:N/K
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:SEE SIGNS AND SYMPTOMS OF
OVEREXPOSURE.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:EYES:NOT EXPECTED TO PRODUCE SIGNIFICANT
IRRITATION ON CONTACT. SKIN:NOT EXPECTED TO CAUSE IRRITATION AFTER
LIMITED, DIRECT CONTACT. INGESTION:EXPECTED TO BE PRACTICALLY
NONTOXIC. INHALATION:HAZARDS A SSOCIATED WITH VAPORS ARE EXPECTED
TO BE LOW.
Medical Cond Aggravated by Exposure:N/K

First Aid

First Aid:EYES:FLUSH WITH LARGE AMOUNTS OF WATER FOR AT LEAST 15
MINUTES. CALL A PHYSICIAN. SKIN:WASH AFFECTED AREA WITH SOAP AND
WATER. INGEST:CALL A PHYSICIAN OR POISON CONTROL CENTER WITH
DETAILED DESCRIPTIO N. INCLUDE POSSIBLE MATERIAL THAT CONTAMINATED
LIQUID DURING USE. INHALATION:IF EXPOSED TO DECOMPOSITION PRODUCTS,
REMOVE PERSON TO FRESH AIR. CALL A PHYSICIAN.

Fire Fighting

Flash Point Method:SCC
Flash Point:NONE
Extinguishing Media:NOT FLAMMABLE
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:TOXIC BY-PRODUCTS MAY FORM UPON
DECOMP.HAZ DECOMP PROD:THERMAL DECOMP MAY PRDCE TRACE AMTS OF HF &
IN SOME CASES PERFLUOROISOBUTYLENE.TRACE DECOMP MAY (SEE SUP)

Accidental Release

Spill Release Procedures:COVER WITH INORGANIC ABSORBENT MATERIAL.
COLLECT SPILLED MATERIAL. PLACE IN A CLOSED CONTAINER. OBSERVE ALL
PRECAUTIONS.
Neutralizing Agent:N/K

Handling

Handling and Storage Precautions:NOT EXPECTED TO PRESENT A HAZ WHEN
USED W/ GOOD INDUS HYGIENE PRACTICES UNDER THE FOLLOWING
CONDITIONS.USE ONLY IN AREAS W/ SUFFICIENT LOC (SEE SUPP)
Other Precautions:AVOID PRLNGD BRTHG OF VAPS.DO NOT BRTH THERMAL DECOMP
PROD.3M REC A CEILING LIM OF 0.01 PPM FOR
PERFLUOROISOBUTYLENE.ACGIH TLV & OSHA PEL FOR HF:2.5 MG/M3 AS
FL.AVOID EYE CONT.DO NOT SMOKE WHEN USING PROD.AFTER FC-70 HAS
BEEN IN (SEE ING 2)

Exposure Controls

Respiratory Protection:IF DECOMPOSITION OCCURS,IN THE ABSENCE OF
ADEQUATE VENTILATION,AN AIR-SUPPLIED RESPIRATOR SHOULD BE WORN.
Ventilation:LOC EXHST VENT W/ A MIN CAPTURE VELOCITY OF 50 LINEAR
FEET/MIN SHOULD BE PROVIDED @/ABOVE BP.IF INTERFERING (SEE ING 2)
Protective Gloves:NONE REQUIRED AT ROOM TEMPERATURE.
Eye Protection:SAFETY GLASSES
Other Protective Equipment:N/K
Work Hygienic Practices:N/K
Supplemental Safety and Health
VP: <0.1000 MMHG. VAP DENS: 28.3 (AIR=1). % VOLAT: 100.00. EXPLO
HAZ:OCCUR AT BP;INCREASED DECOMP AT INCREASED SURF TEMPS. RTE OF
ENTRY:SKIN/INGEST/INHAL .HAZ DECOMP PROD:BP;INCREASED DECOMP AT
INCREASED SURF TEMPS. HNDLG/STOR PREC:EXHST VENT TO MAINTAIN
AIRBORNE CONCENTRATION @ RECOGNIZED HEALTH & SAFETY LEVELS.

Chemical Properties

HCC:N1
Boiling Pt:B.P. Text:419F,215C
Melt/Freeze Pt:M.P/F.P Text:N/K
Decomp Temp:Decomp Text:N/K
Vapor Pres:SEE SUPP
Vapor Density:SEE SUPP
Spec Gravity: 1.900,WATER=1
Evaporation Rate & Reference:<1.00 (BUTYL ACETATE=1)
Solubility in Water:NIL
Appearance and Odor:COLORLESS,CLEAR,ODORLESS LIQUID.
Percent Volatiles by Volume:SUP DA
Corrosion Rate:N/K (FP)

Stability

Stability Indicator/Materials to Avoid:YES
FINELY DIVIDED ACTIVE METALS,ALKALI AND ALKALINE EARTH METALS.
Stability Condition to Avoid:N/K
Hazardous Decomposition Products:THERMAL DECOMP MAY PRDCE TRACE AMTS OF
HF & IN SOME CASES PERFLUOROISOBUTYLENE.TRACE DECOMP MAY OCCUR AT
THE (SEE SUPP)
Conditions to Avoid Polymerization:WILL NOT OCCUR.

Disposal

Waste Disposal Methods:DISPOSAL MUST BE IN ACCORDANCE WITH FEDERAL,
STATE AND LOCAL REGULATIONS . TO RECLAIM OR RETURN, CONTACT YOUR 3M
SALES REPRESENTATIVE. NOT US EPA HAZARDOUS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.